Pc-Check Windows Server IPMI Voltage Sensor Test Failure Information |
Group Number 800X
Device Server
This group contains tests for dedicated servers using the IPMI functionality provided by the server's firmware. If you use the Supermicro IPMI tool application, this should be placed into the group's extra directory in the IPMI subdirectory and called IPMITool.exe
Test Number 307
ERRORCODES & TROUBLESHOOTING
The IPMI program was not found. CODE=0x00/3FF TROUBLESHOOTING0: The IPMI process was unable to run, check that the extra directory is populated and that IPMI commands are supported.
Failed to start the IPMI program. CODE=0x01/3FF TROUBLESHOOTING0: The IPMI process was unable to run, check that the extra directory is populated and that IPMI commands are supported.
Unable to retrieve information from BMC. CODE=0x02/3FF TROUBLESHOOTING0: The IPMI process was unable to run, check that the extra directory is populated and that IPMI commands are supported.
A failure was found in the health check. CODE=0x03/3FF TROUBLESHOOTING1: A failure was found, check the BMC and result log for more information.
The health check reports that the self-test has failed. CODE=0x04/3FF TROUBLESHOOTING1: A failure was found, check the BMC and result log for more information.
A Major error was found in the System Event Log. CODE=0x05/3FF TROUBLESHOOTING1: A failure was found, check the BMC and result log for more information.
A Critical error was found in the System Event Log. CODE=0x06/3FF TROUBLESHOOTING1: A failure was found, check the BMC and result log for more information.
A failed sensor reading was found in the sensor list. CODE=0x07/3FF TROUBLESHOOTING1: A failure was found, check the BMC and result log for more information.
A active alarm was found. CODE=0x08/3FF TROUBLESHOOTING1: A failure was found, check the BMC and result log for more information.
The configured sensor was not found. CODE=0x09/3FF TROUBLESHOOTING1: A failure was found, check the BMC and result log for more information. TROUBLESHOOTING2: A failure was found with the sensors configured, double check the sensor readings in system information or the parameters used.
The sensor reading was below the minimum threshold. CODE=0x0A/3FF TROUBLESHOOTING2: A failure was found with the sensors configured, double check the sensor readings in system information or the parameters used.
The sensor reading was above the maximum threshold. CODE=0x0B/3FF TROUBLESHOOTING2: A failure was found with the sensors configured, double check the sensor readings in system information or the parameters used.
The sensor reading did not match. CODE=0x0C/3FF TROUBLESHOOTING2: A failure was found with the sensors configured, double check the sensor readings in system information or the parameters used. |