Views:

Pc-Check Windows Server IPMI Alarm Test Failure Information

Group Number 800X

 

Device Server

 

This group contains tests for dedicated servers using the IPMI functionality provided by the server's firmware. If you use the Supermicro IPMI tool application, this should be placed into the group's extra directory in the IPMI subdirectory and called IPMITool.exe

 

Test Number 304

IPMI Alarm

This test will check a server's alarm states using the Intelligent Platform Management Interface, if supported. If any active alarms are detected, these will be reported and the test will fail.

Estimated Test Time 1 second.

 

ERRORCODES & TROUBLESHOOTING

 

The IPMI program was not found. CODE=0x00/3FF

TROUBLESHOOTING0: The IPMI process was unable to run, check that the extra directory is populated and that IPMI commands are supported. 

 

Failed to start the IPMI program. CODE=0x01/3FF

TROUBLESHOOTING0: The IPMI process was unable to run, check that the extra directory is populated and that IPMI commands are supported. 

 

Unable to retrieve information from BMC. CODE=0x02/3FF

TROUBLESHOOTING0: The IPMI process was unable to run, check that the extra directory is populated and that IPMI commands are supported. 

 

A failure was found in the health check. CODE=0x03/3FF

TROUBLESHOOTING1: A failure was found, check the BMC and result log for more information. 

 

The health check reports that the self-test has failed. CODE=0x04/3FF

TROUBLESHOOTING1: A failure was found, check the BMC and result log for more information. 

 

A Major error was found in the System Event Log. CODE=0x05/3FF

TROUBLESHOOTING1: A failure was found, check the BMC and result log for more information. 

 

A Critical error was found in the System Event Log. CODE=0x06/3FF

TROUBLESHOOTING1: A failure was found, check the BMC and result log for more information. 

 

A failed sensor reading was found in the sensor list. CODE=0x07/3FF

TROUBLESHOOTING1: A failure was found, check the BMC and result log for more information. 

 

A active alarm was found. CODE=0x08/3FF

TROUBLESHOOTING1: A failure was found, check the BMC and result log for more information. 

 

The configured sensor was not found. CODE=0x09/3FF

TROUBLESHOOTING1: A failure was found, check the BMC and result log for more information. 

TROUBLESHOOTING2: A failure was found with the sensors configured, double check the sensor readings in system information or the parameters used.

 

The sensor reading was below the minimum threshold. CODE=0x0A/3FF

TROUBLESHOOTING2: A failure was found with the sensors configured, double check the sensor readings in system information or the parameters used.

 

The sensor reading was above the maximum threshold. CODE=0x0B/3FF

TROUBLESHOOTING2: A failure was found with the sensors configured, double check the sensor readings in system information or the parameters used.

 

The sensor reading did not match. CODE=0x0C/3FF

TROUBLESHOOTING2: A failure was found with the sensors configured, double check the sensor readings in system information or the parameters used. 

 

Eurosoft (UK) Ltd 
3 St. Stephen's Road 
Bournemouth, Dorset, BH2 6JL 
United Kingdom 
Tel +44 (0)1202 297315 
Fax +44 (0)1202 558280

www.eurosoft-uk.com