Views:

Pc-Check® UEFI

Test Result

System Block Device Linear Read Test Failure Information

Group 7702

Device System Block Device

Provides testing for block based system storage that has only limited BIOS support during the pre-boot phase. Typically this will be embedded flash memory that does not connect via a traditional disk bus such as SATA, SCSI or USB. A typical examples might be eMMC in systems with a mobile form factor.

Test Number 401

Test Name Linear Read

Exercises a drive's read capability using linear (incrementally increasing) read addresses. Success or failure of each read is monitored.

PARAM1: Duration

Time to run the test for in seconds.

PARAM2: Coverage

Percentage coverage.

PARAM3: Maximum Errors

Continues to test until the maximum number of errors is reached, only errors directly associated with reading the drive.

ERRORCODES & TROUBLESHOOTING

The test cannot be executed because something is not supported. CODE="0x00/3FF"

TROUBLESHOOTING1: A program error, such as a memory allocation failure. Check for BIOS updates. The test was inconclusive.

Device_ID VALUE unknown (Exceeds array depth). CODE="0x01/3FF"

TROUBLESHOOTING1: A program error, such as a memory allocation failure. Check for BIOS updates. The test was inconclusive.

Device is too small to test. CODE="0x02/3FF"

TROUBLESHOOTING0: The device appears to be faulty.

Device read failed. CODE="0x03/3FF"

TROUBLESHOOTING0: The device appears to be faulty.

 