Pc-Check Windows Hardware Monitor System Fan Test Failure Information

Group Number 690X

 

Device Hardware Monitor 

 

Hardware Monitor is a group that provides the ability to test Hardware Monitor sensors. The types of sensor available are: temperature, fan speed and voltage. 

All tests within this group have the same structure as follows: 

The test checks the metric (temperature, speed or voltage) is within the percentage tolerance of the target. The user specifies the target value, tolerance and sensor identifier: the test passes if it the sensor value is within plus or minus the tolerance of the target, else it fails. 

 

Test Tolerance 
This is the percentage tolerance the sensor value must be within the target to pass the test. For example, if this is set to 10 and the target is 40C, then the sensor reading must be within 10% of 40C (36C to 44C). 
        
Test Number 315

 

System Fan 

 

System Fan Speed test. The system fan speed is checked and will fail if it is below the configured parameter. If there are multiple system fans then each one will be tested. 

 

Estimated Test Time 1 Second 

 

PARAM8: Minimum Speed

 

Minimum speed of the fan in RPM.

 

ERRORCODES & TROUBLESHOOTING

 

The sensor name parameter was not found. CODE=0x00/3FF

TROUBLESHOOTING0: Check the system information for your system to ensure the correct parameter values are being used.

 

The result was outside the tolerance. CODE=0x01/3FF

TROUBLESHOOTING0: Check the system information for your system to ensure the correct parameter values are being used.

 

The temperature result was outside the tolerance. CODE=0x02/019

TROUBLESHOOTING0: Check the system information for your system to ensure the correct parameter values are being used.

 

Unable to find sensor. CODE=0x03/3FF

TROUBLESHOOTING0: Check the system information for your system to ensure the correct parameter values are being used.

 

Failed to initialise external library in order to perform testing. CODE=0x04/3FF

TROUBLESHOOTING1: Ensure all files are available for testing.

 

The result sensor value is outside the tolerance. Extra information contains the sub-device number. CODE=0x05/01C

TROUBLESHOOTING0: Check the system information for your system to ensure the correct parameter values are being used.