Views:

Optical Deep Read Test Failure Information

Group 6202

Device Optical

This group provides tests optical media devices. Optical device that can be tested are CD-ROM, DVD or Blu-ray drives. There are tests to cover both the mechanical and data read capabilities of the drives from the pre-boot environment. If required, data write tests are available in the Windows diagnostics suite.

Note: Requires suitable data disc media appropriate to the drive type and operating mode to be tested (CD, DVD or Blu-ray).

Note: 'ROM' Data Only Media must be used and ideally of near total capacity to ensure full travel of the device head during tests.

Test Number 404

Test Name  Deep Read

Utilises a specially crafted optical test disk to perform a Deep Read test for enhanced error detection.


PARAM1: Duration

Time to run the test for in seconds.

PARAM3: Maximum Errors

Continues to test until the maximum number of errors is reached, only errors directly associated with reading the drive.

ERRORCODES & TROUBLESHOOTING

The test cannot be executed because something is not supported. CODE="0x00/3FF"
TROUBLESHOOTING1: A program error, such as a memory allocation failure. The test was inconclusive. Check for BIOS updates.

Device_ID VALUE unknown (Exceeds array depth). CODE="0x01/3FF"
TROUBLESHOOTING1: A program error, such as a memory allocation failure. The test was inconclusive. Check for BIOS updates.

Disc is too small to test. CODE="0x02/3FF"
TROUBLESHOOTING2: Unsuitable test media supplied. The test was inconclusive. Please select appropriate test media and try again. Some tests require specialist media.

Device read failed. CODE="0x03/3FF"
TROUBLESHOOTING0: The drive appears to be faulty. Check test media for damage.

Invalid media. CODE="0x04/3FF"
TROUBLESHOOTING2: Unsuitable test media supplied. The test was inconclusive. Please select appropriate test media and try again. Some tests require specialist media.

Wrong block. CODE="0x05/3FF"
TROUBLESHOOTING0: The drive appears to be faulty. Check test media for damage.

Bit walk fail. CODE="0x06/3FF"
TROUBLESHOOTING0: The drive appears to be faulty. Check test media for damage.

CRC failure. CODE="0x07/3FF"
TROUBLESHOOTING0: The drive appears to be faulty. Check test media for damage.

Corrupt data. CODE="0x08/3FF"

TROUBLESHOOTING0: The drive appears to be faulty. Check test media for damage.

Eurosoft (UK) Ltd 
3 St. Stephen's Road 
Bournemouth, Dorset, BH2 6JL 
United Kingdom 
Tel +44 (0)1202 297315 
Fax +44 (0)1202 558280