Views:

Pc-Check Windows Keyboard Keyboard LED Test Failure Information

Group Number 140X

 

Device Keyboard

 

This group covers system information gathering and testing of keyboards.

The Keyboard Zone and Map Tests offer different processes for testing the Keyboards connected to your system. It is not necessary to run both tests for full coverage. Therefore it is recommended to only run the test configured in the way you find most appropriate for your process.

To create a Zone test configuration it is recommended to create a copy of the 104 key configuration and remove any unwanted keys from the file using a text file editor.

Please contact Eurosoft if additional keyboard layouts are required for the Map test.


Test Number 302

Test Name Keyboard LED

The LED test will activate and deactivate the Num lock, Scroll lock and Caps lock LEDs on the keyboards connected to the system to confirm their operation.

Estimated Test Time Dependent on user input.

PARAM4:Time-out

 

The time-out for waiting for a response from the operator.

ERRORCODES & TROUBLESHOOTING

Unable to load any keys to test. CODE="0x00/3FF"

TROUBLESHOOTING0: The specified Key configuration file was not successfully loaded. Check that the file is present and contains keys to be tested.

 

Unable to load the test configuration file. CODE="0x01/3FF"

TROUBLESHOOTING0: The specified Key configuration file was not successfully loaded. Check that the file is present and contains keys to be tested.

 

Unable to get the keyboard. CODE="0x02/001"

TROUBLESHOOTING1: The test failed to start. This is most likely caused by a hardware or OS fault.

 

Unable to create test window. CODE="0x03/001"

TROUBLESHOOTING1: The test failed to start. This is most likely caused by a hardware or OS fault.

 

The Operator chose to fail the test. CODE="0x04/3FF"

TROUBLESHOOTING2: The test failed due to a possible fault with the hardware or due to operator error.

 

The wrong key press was detected. CODE="0x05/011"

TROUBLESHOOTING2: The test failed due to a possible fault with the hardware or due to operator error.

 

Another key was detected during the contact bounce time. CODE="0x06/011"

TROUBLESHOOTING2: The test failed due to a possible fault with the hardware or due to operator error.

 

The test timed out. CODE="0x07/3FF"

TROUBLESHOOTING2: The test failed due to a possible fault with the hardware or due to operator error.

 

The keyboard configuration is invalid. CODE="0x08/3FF"

TROUBLESHOOTING1: The test failed to start. This is most likely caused by a hardware or OS fault.

 

The keyboard can not be un-docked. CODE="0x09/3FF"

TROUBLESHOOTING2: The test failed due to a possible fault with the hardware or due to operator error.

 

A key press or held key was detected CODE="0x0A/011"

TROUBLESHOOTING2: The test failed due to a possible fault with the hardware or due to operator error.

 

Eurosoft (UK) Ltd 
3 St. Stephen's Road 
Bournemouth, Dorset, BH2 6JL 
United Kingdom 
Tel +44 (0)1202 297315 
Fax +44 (0)1202 558280