Symptoms:
When booting the system from the Eurosoft USB device, an error message is displayed: "Configuration Error".
The message persists, and the application continues with default values.
Cause:
The file required to run the software is missing or deleted.
The file on the USB Program Device is corrupt.
The file on the USB Program Device is in the wrong location.
Resolution:
Delete the license file (pccheckuefi.lic) from the USB device in the ROOT folder.
Update the Eurosoft USB plug using the eTestManager application. Retry booting the diagnostics application.
Run the Recovery and Restore Process to put the USB into the expected state.
Frequently Asked Questions:
Q: Where can I find the Recovery and Restore Process?
A: The Recovery and Restore Process can be downloaded from the link below.
Download Link: Recover USB
Q: Where can I find the eTestManager application?
A: The eTestManager application should be available on the same Eurosoft USB Device plug.
A: The eTestManager application can also be downloaded from the link below:
Download Link: eTestManager
Additional Resources:
For more information about Pc-Check UEFI and License error codes, see:
General Support: Home · Customer Self-Service
Knowledge Base: Knowledge Base - Home · Customer Self-Service
Frequently Asked Questions: FAQ · Customer Self-Service
Conclusion:
Booting Pc-Check UEFI requires a correctly configured license file. The license file must be present and configured to support the Pc-Check UEFI product and version.